Technical Specification of Solid Polycarbonate Sheets

The solid polycarbonate panels satisfy the most important construction codes like:

  • CC-1* Category for construction applications (BOCA, ICBO, SBCCI)
  • Underwriters’ laboratory flammability standards (UL 94 and UL 972) for glazing materials.

Macrolux AR

Macrolux Mono AR, GP, SL

Chemical Resistance / ASTM D-1308
ChemicalResistance Time
 Acetone> 24 Hours
Ethylene dichloride> 24 Hours
Unleaded petrol> 24 Hours
Hydrochloric acid (10%)> 24 Hours
Methyl alcohol> 24 Hours
Methylene chloride> 24 Hours
Ketone, methyl alcohol> 24 Hours
Nitric acid (100%)> 24 Hours
Sodium hydroxide (19%)> 24 Hours
Sulfuric acid (1%)> 24 Hours
Toluene> 24 Hours
Isopropanol> 24 Hours
Kerosene> 24 Hours

THERMOFORMING

To thermoform Macrolux Solid sheet is important pre-dry in a dehumidifier oven (circulatory air). The pre-drying time depends on the thickness of the sheet.

Drying Time
Sheet thicknessMaximum temperature of 121 ° CMaximum temperature of 82.2ºC
2.00 mm  2 Hours  4 Hours
3.00 mm  6 Hours14 Hours
4.50 mm12 Hours30 Hours
6.00 mm24 Hours50 Hours

Cold bending

Macrolux Mono GP and SL polycarbonate sheets can be bent cold until a minimum curve radius depending on its thickness. As a rule, the radius of curvature should be equivalent to 100 times the material thickness. R = TX100

R = TX100

Sheet bending based on thickness
Sheet thickness (T)Minimum bend radius (R)
 2.00 mm 20 cms
 3.00 mm 30 cms
 4.50 mm 45 cms
 6.00 mm 60 cms
 9.50 mm 95 cms
12.70 mm127 cms